Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 616
Filtrar
1.
Zhongguo Fei Ai Za Zhi ; 27(3): 179-186, 2024 Mar 20.
Artigo em Chinês | MEDLINE | ID: mdl-38590192

RESUMO

BACKGROUND: Computed tomography guided percutaneous lung biopsy (CT-PLB) is a widely used method for the diagnosis of lung lesions. However, it is invasive, and the most common complications are pneumothorax and pulmonary hemorrhage, which can be life-threatening in severe cases. Therefore, the aim of this study is to analyze the independent risk factors affecting the occurrence of different complications of CT-PLB, so as to reduce the incidence of complications. METHODS: The 605 patients with complete clinical data who underwent CT-PLB in our hospital from May 2018 to December 2019 were retrospectively analyzed. According to the location of the lesions, they were divided into subpleural group and non-subpleural group. The patients were divided into pneumothorax group, pulmonary hemorrhage group, pneumothorax with pulmonary hemorrhage group and non-pneumothorax/pulmonary hemorrhage group according to the complications. The risk factors affecting the incidence of different complications and the independent risk factors of each complication were analyzed. RESULTS: The incidence of pneumothorax was 34.1%, the incidence of pulmonary hemorrhage was 28.1%, and the incidence of pneumothorax complicated with pulmonary hemorrhage was 10.8% (63 cases). The independent risk factor affecting the incidence of subpleural pneumothorax was lesion size (P=0.002). The independent risk factors affecting the occurrence of pneumothorax in the non-subpleural group were plain scan CT value (P=0.035), length of needle through lung tissue (P=0.003), and thickness of needle through chest wall (P=0.020). Independent risk factors affecting the occurrence of pulmonary hemorrhage in the non-subpleural group were length of needle through lung tissue (P<0.001), △CT value of needle travel area (P=0.001), lesion size (P=0.034) and body position (P=0.014). The independent risk factors affecting the co-occurrence of pneumothorax and pulmonary hemorrhage were the length of needle through lung tissue (P<0.001) and the △CT value of needle travel area (P<0.001). CONCLUSIONS: CT-PLB is a safe and effective diagnostic method, which of high diagnostic value for lung lesions. Selecting the appropriate puncture program can reduce complications such as pneumothorax and pulmonary hemorrhage, and improve diagnosis and treatment efficiency.


Assuntos
Pneumopatias , Neoplasias Pulmonares , Pneumotórax , Parede Torácica , Humanos , Pneumotórax/etiologia , Pneumotórax/terapia , Neoplasias Pulmonares/patologia , Estudos Retrospectivos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Pneumopatias/diagnóstico por imagem , Pneumopatias/etiologia , Hemorragia/etiologia , Tomografia Computadorizada por Raios X , Biópsia Guiada por Imagem/efeitos adversos , Fatores de Risco
2.
Zhonghua Yi Xue Za Zhi ; 104(16): 1403-1409, 2024 Apr 23.
Artigo em Chinês | MEDLINE | ID: mdl-38644291

RESUMO

Objective: To investigate the safety and accuracy of CT-guided intracranial puncture biopsy and the possible influencing factors of postoperative bleeding complications. Methods: A case series study. A retrospective analysis was conducted on 101 patients who underwent CT-guided intracranial puncture biopsy at the First Affiliated Hospital of Zhengzhou University from January 2017 to December 2021. The basic data of patients and the safety and accuracy of CT-guided intracranial puncture biopsy were analyzed statistically. Univariate and multivariate logistic regression analysis were used to screen the influencing factors of bleeding complications in CT-guided intracranial puncture biopsy, and the bleeding complications in glioma subgroup were analyzed. Results: Among the 101 patients, 53 were males and 48 were females, aged (53.7±17.2) years. The average diameter of intracranial lesions was (3.5±1.4) cm, while the vertical distance from the lesion to the meninges was (2.4±1.7) cm. The needle's intracranial depth reached (3.2±1.8) cm, with adjustments averaging (3±1) occurrences and an average procedural duration of (40.2±12.9) minutes. Pathological diagnoses included glioma (36 cases), gliosis (3 cases), lymphoma (32 cases), metastatic tumors (7 cases), inflammatory lesions (13 cases), and 10 indeterminate cases. The positive rate of puncture pathology was 90.1% (91/101), and the diagnostic coincidence rate was 94.0% (78/83). The incidence of bleeding complications in CT-guided intracranial puncture biopsy was 26.7% (27/101), of which 23 cases had small intratoma or needle path bleeding, 4 cases had massive bleeding, and 2 cases died. The patients were divided into bleeding group (n=27) and no bleeding group (n=74), according to the presence or absence of bleeding. The results of univariate logistic regression analysis showed that thrombin time≥15 s and the number of needle adjustment were the factors affecting the occurrence of bleeding complications (both P<0.05), and the results of multivariate logistic regression showed that thrombin time≥15 s was the related factor for bleeding. Patients with thrombin time≥15 s had a 3.045 times higher risk of bleeding than those with thrombin time<15 s (OR=3.045,95%CI:1.189-7.799,P=0.020). Among the 101 patients, 36 cases of midbrain glioma were divided into low-grade glioma group (n=11) and high-grade glioma group (n=25) according to the pathological grade. Subgroup analysis showed that the risk of bleeding for high-grade gliomas was 9.231 times higher than that for low-grade gliomas (OR=9.231,95%CI:1.023-83.331,P=0.031). Conclusions: CT-guided intracranial puncture biopsy is safe and feasible with high accuracy. Complication rates are associated with thrombin time≥15 s, especially high-grade glioma, which increases the risk of postoperative bleeding.


Assuntos
Neoplasias Encefálicas , Biópsia Guiada por Imagem , Tomografia Computadorizada por Raios X , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Biópsia Guiada por Imagem/efeitos adversos , Biópsia Guiada por Imagem/métodos , Glioma/patologia , Adulto , Idoso , Encéfalo/patologia , Biópsia por Agulha/efeitos adversos , Biópsia por Agulha/métodos
3.
Sci Rep ; 14(1): 7348, 2024 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-38538978

RESUMO

To evaluate the current incidence of pulmonary hemorrhage and the potential factors contributing to its increased risk after percutaneous CT-guided pulmonary nodule biopsy and to summarize the technical recommendations for its treatment. In this observational study, patient data were collected from ten medical centers from April 2021 to April 2022. The incidence of pulmonary hemorrhage was as follows: grade 0, 36.1% (214/593); grade 1, 36.8% (218/593); grade 2, 18.9% (112/593); grade 3, 3.5% (21/593); and grade 4, 4.7% (28/593). High-grade hemorrhage (HGH) occurred in 27.2% (161/593) of the patients. The use of preoperative breathing exercises (PBE, p =0.000), semiautomatic cutting needles (SCN, p = 0.004), immediate contrast enhancement (ICE, p =0.021), and the coaxial technique (CoT, p = 0.000) were found to be protective factors for HGH. A greater length of puncture (p =0.021), the presence of hilar nodules (p = 0.001), the presence of intermediate nodules (p = 0.026), a main pulmonary artery diameter (mPAD) larger than 29 mm (p = 0.015), and a small nodule size (p = 0.014) were risk factors for high-grade hemorrhage. The area under the curve (AUC) was 0.783. These findings contribute to a deeper understanding of the risks associated with percutaneous CT-guided pulmonary nodule biopsy and provide valuable insights for developing strategies to minimize pulmonary hemorrhage.


Assuntos
Anormalidades Cardiovasculares , Pneumopatias , Neoplasias Pulmonares , Nódulo Pulmonar Solitário , Humanos , Incidência , Pneumopatias/diagnóstico por imagem , Pneumopatias/epidemiologia , Pneumopatias/etiologia , Hemorragia/epidemiologia , Hemorragia/etiologia , Biópsia Guiada por Imagem/efeitos adversos , Tomografia Computadorizada por Raios X/métodos , Fatores de Risco , Estudos Retrospectivos , Anormalidades Cardiovasculares/etiologia , Neoplasias Pulmonares/patologia , Nódulo Pulmonar Solitário/diagnóstico por imagem
6.
J R Coll Physicians Edinb ; 54(1): 14-17, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38379306

RESUMO

BACKGROUND: Physician-led thoracic ultrasound (TUS)-guided biopsies provide a prompt route to tissue diagnosis in pleural and peripheral lung malignancies. This retrospective study reviews the diagnostic performance and safety of this approach in a UK District General Hospital. METHODS: Time to biopsy, diagnostic yield and complication rate were analysed in a cohort of 49 patients undergoing ultrasound-guided tissue sampling between September 2019 and December 2022. RESULTS: Fifty-one TUS-guided biopsies were attempted. Mean time from decision to biopsy was 5 days. The overall diagnostic yield was 82%. Complication rate was low; 3 minor adverse effects were reported which led to no change in routine care. CONCLUSION: This single centre retrospective study shows that physician-led TUS-guided biopsy provides a safe and timely method of obtaining a tissue diagnosis in thoracic malignancy. It offers an alternative to computer tomography (CT)-guided or thoracoscopic biopsies and should be considered in selected patients where local procedural expertise exists.


Assuntos
Hospitais Gerais , Médicos , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Biópsia Guiada por Imagem/efeitos adversos , Biópsia , Ultrassonografia de Intervenção/efeitos adversos , Ultrassonografia de Intervenção/métodos
8.
Acta Neurochir (Wien) ; 166(1): 67, 2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38319393

RESUMO

PURPOSE: User-friendly robotic assistance and image-guided tools have been developed in the past decades for intraparenchymal brain lesion biopsy. These two methods are gradually becoming well accepted and are performed at the discretion of the neurosurgical teams. However, only a few data comparing their effectiveness and safety are available. METHODS: Population-based parallel cohorts were followed from two French university hospitals with different surgical methods and defined geographical catchment regions (September 2019 to September 2022). In center A, frameless robot-assisted stereotactic intraparenchymal brain lesion biopsies were performed, while image-guided intraparenchymal brain lesion biopsies were performed in center B. Pre-and postoperative clinical, radiological, and histomolecular features were retrospectively collected and compared. RESULTS: Two hundred fifty patients were included: 131 frameless robot-assisted stereotactic intraparenchymal brain lesion biopsies in center A and 119 image-guided biopsies in center B. The clinical, radiological, and histomolecular features were comparable between the two groups. The diagnostic yield (96.2% and 95.8% respectively; p = 1.000) and the overall postoperative complications rates (13% and 14%, respectively; p = 0.880) did not differ between the two groups. The mean duration of the surgical procedure was longer in the robot-assisted group (61.9 ± 25.3 min, range 23-150) than in the image-guided group (47.4 ± 11.8 min, range 25-81, p < 0.001). In the subgroup of patients with anticoagulant and/or antiplatelet therapy administered preoperatively, the intracerebral hemorrhage > 10 mm on postoperative CT scan was higher in the image-guided group (36.8%) than in the robot-assisted group (5%, p < 0.001). CONCLUSION: In our bicentric comparative study, robot-assisted stereotactic and image-guided biopsies have two main differences (shorter time but more frequent postoperative hematoma for image-guided biopsies); however, both techniques are demonstrated to be safe and efficient.


Assuntos
Robótica , Humanos , Estudos Retrospectivos , Biópsia Guiada por Imagem/efeitos adversos , Anticoagulantes , Encéfalo
9.
J Med Case Rep ; 18(1): 41, 2024 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-38308348

RESUMO

BACKGROUND: The kidney biopsy is a routine procedure. Once an indication has been established, the benefit-risk balance may be considered. Sometimes, even with effective treatment, a severe complication may develop. CASE PRESENTATION: We present the case of a Caucasian 20-year-old young woman admitted to investigating and treating acute kidney injury. Renal involvement was characterized by kidney damage requiring hemodialysis treatment, positive immunologic testing, 0.5 g/day proteinuria, and microscopic hematuria. Contraindications were excluded, so an ultrasound-guided kidney biopsy was performed. To reduce the bleeding complication, Octostim (desmopressin) was administered. There were no direct complications following the kidney biopsy, so we continued the immunosuppressive treatment. Histologically founded thrombotic microangiopathy. However, 1 week later, severe bleeding developed with the need for urgent surgical left kidney removal. CONCLUSION: Kidney biopsy can be considered a routine procedure, and various bleeding episodes are most common in terms of complications, the detection of which is essential. Delayed bleeding complications are rare and can be caused by minor injuries. Our young patient had no injury during the hospitalization. We hypothesized that the developed serious and delayed bleeding complication resulted from effective immunosuppressive treatment. To the best of our knowledge, this is the first such case to date. However, renal biopsy in the case of thrombotic microangiopathy requires caution.


Assuntos
Injúria Renal Aguda , Microangiopatias Trombóticas , Feminino , Humanos , Adulto Jovem , Adulto , Rim/patologia , Nefrectomia/efeitos adversos , Microangiopatias Trombóticas/etiologia , Microangiopatias Trombóticas/diagnóstico , Injúria Renal Aguda/etiologia , Injúria Renal Aguda/patologia , Biópsia Guiada por Imagem/efeitos adversos , Imunossupressores/efeitos adversos , Biópsia/efeitos adversos
12.
BMC Pulm Med ; 24(1): 33, 2024 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-38218792

RESUMO

OBJECTIVE: This study aimed to assess the incidence and clinical significance of pneumothorax (PTX) and pulmonary hemorrhage (PH) after percutaneous transthoracic lung biopsy (PTLB) guided by C-arm cone-beam computed tomography (CBCT). Furthermore, this study aimed to examine the relationships between PTX and PH with demographics, clinical characteristics, imaging, and PTLB parameters. METHODS: A retrospective analysis was conducted on 192 patients who underwent PTLB at our hospital between January 2019 and October 2022. Incidences of PTX and PH were recorded. PTX was considered clinically significant if treated with chest tube insertion (CTI), and PH if treated with bronchoscopes or endovascular treatments. The various factors on PTX and PH were analyzed using the Chi-squared test and Student t-test. Logistic regression analyses were then used to determine these factors on the correlation to develop PTX and PH. RESULTS: PTX occurred in 67/192 cases (34.9%); CTI was required in 5/67 (7.5%). PH occurred in 63/192 cases (32.8%) and none of these cases required bronchoscopes or endovascular treatments. Lesion diameter (ORPTX = 0.822; ORPH = 0.785), presence of pulmonary emphysema (ORPH = 2.148), the number of samples (ORPH = 1.834), the use of gelfoam (ORPTX = 0.474; ORPH = 0.341) and ablation (ORPTX = 2.351; ORPH = 3.443) showed statistically significant correlation to PTX and PH. CONCLUSIONS: CBCT-guided PTLB is a safe and effective method for performing lung biopsies. The use of gelfoam has been shown to reduce the occurrence of PTX and PH. However, caution should be exercised when combining radiofrequency ablation with PTLB, as it may increase the risk of PTX and PH.


Assuntos
Pneumopatias , Pneumotórax , Humanos , Pneumotórax/epidemiologia , Pneumotórax/etiologia , Pneumotórax/patologia , Incidência , Estudos Retrospectivos , Relevância Clínica , Pulmão/diagnóstico por imagem , Pulmão/patologia , Pneumopatias/diagnóstico por imagem , Pneumopatias/epidemiologia , Pneumopatias/complicações , Tomografia Computadorizada de Feixe Cônico , Hemorragia/epidemiologia , Hemorragia/etiologia , Biópsia por Agulha/efeitos adversos , Biópsia Guiada por Imagem/efeitos adversos , Biópsia Guiada por Imagem/métodos , Fatores de Risco
13.
Radiology ; 310(1): e230453, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38259204

RESUMO

Background Splenic biopsy is rarely performed because of the perceived risk of hemorrhagic complications. Purpose To evaluate the safety of large bore (≥18 gauge) image-guided splenic biopsy. Materials and Methods This retrospective study included consecutive adult patients who underwent US- or CT-guided splenic biopsy between March 2001 and March 2022 at eight academic institutions in the United States. Biopsies were performed with needles that were 18 gauge or larger, with a comparison group of biopsies with needles smaller than 18 gauge. The primary outcome was significant bleeding after the procedure, defined by the presence of bleeding at CT performed within 30 days or angiography and/or surgery performed to manage the bleeding. Categorical variables were compared using the χ2 test and medians were compared using the Mann-Whitney test. Results A total of 239 patients (median age, 63 years; IQR, 50-71 years; 116 of 239 [48.5%] female patients) underwent splenic biopsy with an 18-gauge or smaller needle and 139 patients (median age, 58 years [IQR, 49-69 years]; 66 of 139 [47.5%] female patients) underwent biopsy with a needle larger than 18 gauge. Bleeding was detected in 20 of 239 (8.4%) patients in the 18-gauge or smaller group and 11 of 139 (7.9%) in the larger than 18-gauge group. Bleeding was treated in five of 239 (2.1%) patients in the 18-gauge or smaller group and one of 139 (1%) in the larger than 18-gauge group. No deaths related to the biopsy procedure were recorded during the study period. Patients with bleeding after biopsy had smaller lesions compared with patients without bleeding (median, 2.1 cm [IQR, 1.6-5.4 cm] vs 3.5 cm [IQR, 2-6.8 cm], respectively; P = .03). Patients with a history of lymphoma or leukemia showed a lower incidence of bleeding than patients without this history (three of 90 [3%] vs 28 of 288 [9.7%], respectively; P = .05). Conclusion Bleeding after splenic biopsy with a needle 18 gauge or larger was similar to biopsy with a needle smaller than 18 gauge and seen in 8% of procedures overall, with 2% overall requiring treatment. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Grant in this issue.


Assuntos
Biópsia Guiada por Imagem , Agulhas , Baço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Angiografia , Biópsia Guiada por Imagem/efeitos adversos , Agulhas/efeitos adversos , Agulhas/estatística & dados numéricos , Estudos Retrospectivos , Baço/diagnóstico por imagem , Baço/patologia , Idoso
14.
Korean J Radiol ; 25(2): 157-165, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38288896

RESUMO

OBJECTIVE: We aimed to evaluate the clinical and imaging factors associated with hemorrhagic complications and patient discomfort following ultrasound (US)-guided breast biopsy. MATERIALS AND METHODS: We prospectively enrolled 94 patients who were referred to our hospital between June 2022 and December 2022 for US-guided breast biopsy. After obtaining informed consent, two breast radiologists independently performed US-guided breast biopsy and evaluated the imaging findings. A hemorrhagic complication was defined as the presence of bleeding or hematoma on US. The patients rated symptoms of pain, febrile sensation, swelling at the biopsy site, and dyspnea immediately, 20 minutes, and 2 weeks after the procedure on a visual analog scale, with 0 for none and 10 for the most severe symptoms. Additional details recorded included those of nausea, vomiting, bleeding, bruising, and overall satisfaction score. We compared the clinical symptoms, imaging characteristics, and procedural features between patients with and those without hemorrhagic complications. RESULTS: Of 94 patients, 7 (7%) developed hemorrhagic complications, while 87 (93%) did not. The complication resolved with 20 minutes of manual compression, and no further intervention was required. Vascularity on Doppler examination (P = 0.008), needle type (P = 0.043), and lesion location (P < 0.001) were significantly different between the groups. Patients with hemorrhagic complications reported more frequent nausea or vomiting than those without hemorrhagic complications (29% [2/7] vs. 2% [2/87], respectively; P = 0.027). The overall satisfaction scores did not differ between the two groups (P = 0.396). After 2 weeks, all symptoms subsided, except bruising (50% 2/4 in the complication group and 25% [16/65] in the no-complication group). CONCLUSION: US-guided breast biopsy is a safe procedure with a low complication rate. Radiologists should be aware of hemorrhagic complications, patient discomfort, and overall satisfaction related to this procedure.


Assuntos
Biópsia Guiada por Imagem , Ultrassonografia de Intervenção , Humanos , Estudos Prospectivos , Biópsia por Agulha/métodos , Biópsia Guiada por Imagem/efeitos adversos , Biópsia Guiada por Imagem/métodos , Ultrassonografia de Intervenção/métodos , Assistência Centrada no Paciente , Náusea/etiologia , Vômito/etiologia
15.
Clin Radiol ; 79(4): 263-271, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38220515

RESUMO

AIM: To investigate the diagnostic performance of computed tomography (CT)-guided percutaneous transthoracic needle biopsy (PTNB) for thymic epithelial tumours (TETs) and the complication rate after PTNB including seeding after PTNB. MATERIALS AND METHODS: This retrospective study identified PTNBs for anterior mediastinal lesions between May 2007 and September 2021. The diagnostic performance for TETs and complications were investigated. The concordance of the histological grades of TETs between PTNB and surgery was evaluated. The factors associated with pleural seeding after PTNB were determined using Cox regression analysis. RESULTS: Of 387 PTNBs, 235 PTNBs from 225 patients diagnosed as TETs (124 thymomas and 101 thymic carcinomas) and 150 PTNBs from 133 patients diagnosed as other than TETs were included. The sensitivity, specificity, and accuracy for TETs were 89.4% (210/235), 100% (210/210), and 93.5% (360/385), respectively, with an immediate complication rate of 4.4% (17/385). The concordance rate of the histological grades between PTNB and surgery was 73.3% (77/105) after excluding uncategorised types of thymomas. During follow-up after PTNB (median duration, 38.8 months; range, 0.3-164.6 months), no tract seeding was observed. Pleural seeding was observed in 26 patients. Thymic carcinoma (hazard ratio [HR], 5.94; 95% confidence interval [CI], 2.07-17.08; p=0.001) and incomplete resection (HR, 3.29; 95% CI, 1.20-9.02; p=0.02) were associated with pleural seeding, while the biopsy approach type (transpleural versus parasternal) was not associated (p=0.12). CONCLUSIONS: Pretreatment biopsy for TETs was accurate and safe and may be considered for diagnosing TETs, particularly when the diagnosis is challenging and histological diagnosis is mandatory.


Assuntos
Neoplasias Epiteliais e Glandulares , Timoma , Neoplasias do Timo , Humanos , Timoma/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Biópsia por Agulha/métodos , Biópsia Guiada por Imagem/efeitos adversos , Biópsia Guiada por Imagem/métodos , Neoplasias do Timo/diagnóstico por imagem , Neoplasias Epiteliais e Glandulares/diagnóstico por imagem
16.
Fr J Urol ; 34(1): 102547, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37858376

RESUMO

BACKGROUND: MRI-guided biopsy (MGB) contributes to the diagnosis of clinically significant Prostate Cancer (csPCa). However, there are no clear recommendations for the management of men after a negative MGB. The aim of this study was to assess the risk of csPCa after a first negative MGB. METHODS: Between 2014 and 2020, we selected men with a PI-RADS score ≥ 3 on MRI and a negative MGB (showing benign findings) performed for suspected prostate cancer. MGB (targeted and systematic biopsies) was performed using fully integrated mobile fusion imaging (KOELIS). The primary endpoint was the rate of csPCa (defined as an ISUP grade ≥ 2) diagnosed after a first negative MGB. RESULTS: A total of 381 men with a negative MGB and a median age of 65 (IQR: 59-69, range: 46-85) years were included. During the median follow-up of 31 months, 124 men (32.5%) had a new MRI, and 76 (19.9%) were referred for a new MGB, which revealed csPCa in 16 (4.2%) of them. We found no statistical difference in the characteristics of men diagnosed with csPCa compared with men with no csPCa after the second MGB. CONCLUSION: We observed a risk of significant prostate cancer in 4% of men two years after a negative MRI-guided biopsy. Performing a repeat MRI could improve the selection of men who will benefit from a repeat MRI-guided biopsy, but a clear protocol is needed to follow these patients.


Assuntos
Imagem por Ressonância Magnética Intervencionista , Neoplasias da Próstata , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Biópsia Guiada por Imagem/efeitos adversos , Ultrassonografia de Intervenção/métodos , Imagem por Ressonância Magnética Intervencionista/métodos
17.
Int Urol Nephrol ; 56(3): 819-826, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37902926

RESUMO

PURPOSE: To calculate the frequency of infection and acute urinary retention (AUR) following transperineal (TP) prostate biopsy at a single high-volume academic institution and determine risk factors for developing these post-biopsy conditions. METHODS: Men undergoing TP prostate biopsy from 2012 to 2022 at our institution were retrospectively identified and chart reviewed. TP biopsies were performed with TR ultrasound (TRUS) guidance with anesthesia using a brachytherapy grid template. TRUS volumes were recorded during the procedure, and magnetic resonance imaging (MRI) volumes were calculated using the ellipsoid formula. When available, MRI volume was used for all analysis, and when absent, TRUS volume was used. AUR was defined as requiring urinary catheter placement within 72 h post-biopsy for inability to urinate. Univariable analysis was performed and variables with p < 0.1 and/or established clinical relevance were included in a backward binary logistic regression to produce an optimized model that fit the data without collinearity between variables. RESULTS: A total of 767 TP biopsies were completed in the study window. The frequency of infection was 1.83% (N = 14/767). The total frequency of AUR was 5.48% (N = 42/767). On multivariable regression, patients who went into AUR were five times as likely to develop infection (p = 0.020). Patients with infection post-TP biopsy were four times as likely to develop AUR (p = 0.047) and with prostates > 61.21 cc were three times as likely (p = 0.019). CONCLUSION: According to our model, AUR is the greatest risk factor for infection post-TP biopsy. With regard to AUR risks, infection post-biopsy and prostate size > 61.21 cc are the greatest risk factors.


Assuntos
Neoplasias da Próstata , Retenção Urinária , Masculino , Humanos , Próstata/patologia , Neoplasias da Próstata/patologia , Retenção Urinária/epidemiologia , Retenção Urinária/etiologia , Estudos Retrospectivos , Biópsia/métodos , Fatores de Risco , Biópsia Guiada por Imagem/efeitos adversos
18.
J Urol ; 211(2): 205-213, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37976319

RESUMO

PURPOSE: Transrectal prostate biopsy has come under scrutiny due to potential for postbiopsy infections and transperineal prostate biopsy is being offered as the safer alternative. However, there is a lack of randomized comparative studies. Our goal was to directly evaluate infectious and noninfectious complications following the 2 biopsy procedures. MATERIALS AND METHODS: We conducted a prospective, pragmatic, randomized clinical study in men undergoing prostate biopsy. The participants underwent either transrectal or transperineal prostate biopsy in the office under local anesthesia. The primary outcome was a 30-day composite infectious complication rate, comprising of 1 or more components including fever, genitourinary infection, antibiotic prescriptions, office or emergency visits, hospitalization, or sepsis. Secondary outcomes included 30-day composite noninfectious complications (urinary or hemorrhagic). RESULTS: Of the 763 randomized participants, 718 underwent either transrectal (351) or transperineal (367) prostate biopsy. A composite infectious complication event occurred in 9 participants (2.6%) in the transrectal and 10 participants (2.7%) in the transperineal group (odds ratio, 1.06; 95% CI, 0.43 to 2.65; P = .99). None of the participants developed sepsis in either group. There were no between-group differences in any of the individual component infectious events. A composite noninfectious complication occurred in 6 (1.7%) and 8 (2.2%) participants in the transrectal and transperineal groups, respectively (odds ratio, 1.28; 95% CI, 0.44 to 3.73; P = .79). No participants required hospitalization or other interventions. CONCLUSIONS: Among men undergoing transperineal or transrectal prostate biopsy, we could not demonstrate any difference in the infectious or noninfectious complications. Both biopsy approaches remain clinically viable and safe.


Assuntos
Neoplasias da Próstata , Sepse , Humanos , Masculino , Biópsia/métodos , Biópsia Guiada por Imagem/efeitos adversos , Biópsia Guiada por Imagem/métodos , Estudos Prospectivos , Próstata/patologia , Neoplasias da Próstata/patologia , Reto/patologia , Sepse/epidemiologia , Sepse/etiologia
19.
BJU Int ; 133(3): 324-331, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38009392

RESUMO

OBJECTIVES: To report a single-centre experience of a complete transition from transrectal (TR) to transperineal (TP) prostate biopsy under local anaesthesia using a freehand cognitive coaxial approach and without use of antibiotic prophylaxis. PATIENTS AND METHODS: Analysis was performed of a prospective database of patients undergoing prostate biopsy performed by four surgeons between 1 June 2018 and 31 May 2022. Outcomes of interest were complications, cancer detection rate, inter-operator reliability, and tolerability. RESULTS: Overall, 1915 patients underwent 2337 separate prostate biopsy sessions. Only 2.4% patients in the TP group received antibiotic prophylaxis, while 100% received antibiotics in the TR group. The complication rate was significantly lower in the TP group compared to the TR group (0.3% vs 5.0%, P < 0.001). In contrast to the TR group, there were no cases of urosepsis or admissions to intensive care in the TP group. The total cancer detection rate by TP biopsy was 70% and the overall pathology detection rate was 88.4%. There was no difference in cancer or pathology detection between operators. A stable level of cancer detection was reached early on for both Prostate Imaging-Reporting and Data System 4 and 5 lesions. All cases performed were performed successfully without need for early termination. CONCLUSION: Implementing a complete transition from TR to TP biopsy can result in a significant reduction in complications and hospital re-admissions. A cognitive freehand coaxial technique is well tolerated by patients and achieves a high cancer detection rate.


Assuntos
Próstata , Neoplasias da Próstata , Masculino , Humanos , Próstata/patologia , Neoplasias da Próstata/patologia , Reto , Reprodutibilidade dos Testes , Períneo/patologia , Biópsia/efeitos adversos , Biópsia/métodos , Cognição , Biópsia Guiada por Imagem/efeitos adversos , Biópsia Guiada por Imagem/métodos
20.
Nephron ; 148(1): 16-21, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37429269

RESUMO

INTRODUCTION: Kidney biopsy is the cornerstone for the diagnosis of glomerular diseases and to guide treatment. Percutaneous ultrasound-guided kidney biopsy is currently the gold standard to obtain cortical specimens. However, in cases where ultrasound-guided kidney biopsy is not deemed safe (obese patients, deep kidneys, or kidneys with a complicated anatomy), CT-guided kidney biopsy could be a convenient alternative to obtain renal tissue samples. The aim of this study was to describe the diagnostic yield and complications of CT-guided kidney biopsies in patients with glomerular diseases that were previously discarded for ultrasound-guided kidney biopsy. MATERIAL AND METHODS: We performed a retrospective, single-center, observational study including patients who underwent CT-guided native kidney biopsies in our center after being contraindicated for ultrasound-guided biopsy. Patients' records were reviewed retrieving baseline characteristics and pre-biopsy clinical, laboratory parameters and concomitant medication. The biopsy needle gauge, site of puncture, and number of needle passes were recorded. The diagnostic yield was evaluated by the number of glomeruli obtained, the rate of specimens that were adequate to reach diagnosis, and the number of biopsies that had to be repeated. Complications were defined as minor (hypotension, hematoma) and major (arteriovenous fistulae, major bleeding requiring embolization, or nephrectomy). The diagnostic yield and complications were compared to ultrasound-guided native kidney biopsies performed during the same period. RESULTS: 56 CT-guided native kidney biopsies were performed during the study period. The number of glomeruli obtained per patient was 11.5 ± 6.3, which was inferior to that obtained from ultrasound-guided biopsies (14.08 ± 8.47, p < 0.05). However, the rate of specimens that were adequate to reach a diagnosis was similar (92.9% vs. 90.8%, p = 0.437). The number of needle passes was higher in CT-guided kidney biopsies (2.0 ± 0.7 vs. 1.7 ± 0.5, p < 0.05), as well as the incidence of post-biopsy perirenal asymptomatic hematomas (66.1% vs. 24.5%, p < 0.01). There were no significant differences in other post-biopsy minor complications (1.8% vs. 2.5%, p = 0.621). There were no major complications after CT-guided kidney biopsies. CONCLUSIONS: CT-guided percutaneous kidney biopsy is a valid alternative for the diagnosis of glomerular diseases in patients with special characteristics such as obesity or deep kidneys that contraindicate ultrasound-guided biopsy. In this population, CT-guided kidney biopsies are safe and provide a high diagnostic yield, reaching a diagnosis in >90% of patients that had been previously discarded for ultrasound-guided biopsy.


Assuntos
Nefropatias , Rim , Humanos , Estudos Retrospectivos , Rim/diagnóstico por imagem , Rim/patologia , Nefropatias/patologia , Biópsia Guiada por Imagem/efeitos adversos , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...